Fault Severity Date Description Initials > Date Action Initials Status

Historical faultlog brought forward from 2014 ...

Fault Severity Date Description Initials > Date Action Initials Status
14029 HIGH 2014.09.01 Primary mirror is filthy csj 2014.09.23 Cleaned with First Contact Polymer Cleaner (some residue) csj
13028 HIGH 2013.02.02 Substantial direct light ingress from bollard lamps: Screen on dome side csj has this been done ?
13027 MEDIUM 2013.02.02 Reduce lights on autofocus handset csj
13026 HIGH 2013.01.14 Dome HOME locator magnet missing csj 2013.01.14 Magnet dropped off and located on opposite magnet. Replaced jaf Closed
12025 HIGH 2012.11.21 Dome rotation failed csj 2012.11.22 Repair effected. See emails for further comments jaf MONITOR
12024 MEDIUM 2012.11.21 Dome LED light strips failed csj 2012.12.01 Light strips replaced jaf Closed
12023 LOW 2012.11.16 Dome exterior requires cleaning csj 2013.10.23+ Dome Cleaned jar Closed
12022 MEDIUM 2012.11.16 Underfloor cable ducting is excessively wet jaf 2012.11 Dessicant bags purchased and placed in ducts jaf MONITOR
12021 2012.11.09 Z #3 (driving filterwheel faulty csj 2012.11.15 FW replaced by Z #5, New controllers bought csj Closed
12020 2012.02.01 Filterwheel initialisation cannot be done remotely csj 2012.11.12 Requires relay on power line in USB cable. Added and powered by Z-wave controller jaf Closed
12019 2012.10.21 H36 Camera failed whilst observing csj 2012.10.22 Power cable too short, slew to south disconnected power supply.
Cable extended
jaf Closed
12018 MEDIUM 2012.10.10 Main mirror very dusty: requires cleaning csj/jaf See 14029 csj Closed
12017 LOW 2012.10.08 Desk illumination: we require
* red light with varo, (e.g. RS multi-turn dial BF80-6A £6.13)
* keyboard with switchable illumination (e.g. logitech illuminated keyboard £54 )
* move main light switch to side of door
csj
2012.10.12

keyboard installed
hmm
12016 2012.10.06 Extreme condensation on mirror as T drops csj 2012.10.08 checked -- mostly dust, but check for condensation on cold mornings csj Closed
12014 MEDIUM 2012.10.05 Too much scattered light inside and outside dome
Require light baffle for OTA (PlaneWave $150)
Require baffle south of light over library door
csj 2012.10.08 South-side floods and orrery bollards switched from library
Baffle fitted
csj
12013 2012.10.05 Maxim DL requires 5s guider settling delay after every exposure
This is disastrous for fast photometry (eg 10 s exposures)
csj 2012.10.05 Maxim DL : Guide Tab : Options : Guider Settling :
Uncheck considered settled, select ridiculous large number in box below
csj Closed
12011 2012.09.25 Tripping hazards identified: uneven floor and floor-level equipment csj 2012.10.05 RS mats installed jaf Closed
12010 MEDIUM 2012.09.25 Can dome heater and dehumidifier be placed under VERA control ? csj 2012.09.25 heater: 1m-4-way extension cable installed, heater on VERA
dehumidifier: requires unit which restarts in previous mode on power-up
jaf Closed
12009 2012.09.25 How is internal dome logger accessed?
Can dome conditions be posted to a web page for monitoring ?
csj 2012.09.25 ELUSBRT.exe identified on PC.
Only accessible on PC at present.
csj Closed
12008 2012.09.25 Autoguider to be moved to finder scope csj 2012.10.03 Autoguider works well on main scope -- leave well alone csj Closed
12007 LOW 2012.09.25 Telescope requires rebalancing csj 2012.09.25
RA axis rebalanced, requires protector on balance arm
Dec axis top heavy, require weights on bottom of mirror cell
csj
12006 2012.08.10 Key for PC security cable lock missing csj 2012.09.26 key located csj Closed
12005 2012.08.10 Telephone inoperative csj 2012.09.15 Phone base station located and rebooted. Extension number 191 hmm Closed
12004 2012.02 Door frame requires stiffener on upper edge csj 2012.10.22 Stiffener fixed jaf Closed
12003 2012.02 Ethernet cable on Vera unit too long csj 2012.11.16 Sorted csj Closed
12002 2012.02 Loose contacts on shutter battery power charger csj 2012.08.09 Contact box refixed jaf Closed
12001 2012.08 Aurora cloud sensor failed jaf 2012.08 Cable disconnected, heater not in use, detectors corroded
Replaced with Boltwood Cloud Sensor
jaf Closed